Piston/Barrel Matching
Top-end Service Limits
Specifications
Standard
Service Limit
Piston Tolerance
0.028-0.043mm
(replacement)
0.07mm
Ring End Gap
0.55mm
0.65mm
Gudgeon Pin O/D
14.994-15.000mm
14.980mm
Con' Rod
Small End I/D
19.002-19.014mm
19.022mm